COVID-19 Rapid Testing Kit With 97%+ Accuracy

TUV CE,ISO13485,CFDA,EUA ect approved rapid testing kit with 97%+ accuracy!
15 minutes know the result
Price under 10USD/TEST,fast delivery time!
Chat Now

Product Details


Measurement Principle

The product is based on the principle of antigen-antibody reaction and immunoassay technique. The test device contains colloidal gold labeled SARS-CoV-2 recombinant protein, mouse-anti human IgG antibody immobilized in G test area, mouse-anti human IgM antibody immobilized in M test area and the  corresponding antibody in quality control area (C). During the test, when the SARS-CoV-2 IgM antibody level in the  sample is at or above the limit of detection of the test, the SARS-CoV-2 IgM antibody in the sample binds to the colloidal  gold labeled SARS-CoV-2 recombinant protein which is  pre-coated on a gold label pad. The conjugates migrate upward through capillary effect and would be captured by mouse-anti human IgM antibody immobilized in M test area subsequently and this produces a purple-red band appears in the M test area. When the SARS-CoV-2 IgG antibody level in the sample is at or  above the limit of detection of the test, the SARS-CoV-2 IgG  antibody in the sample binds to the colloidal gold labeled  SARS-CoV-2 recombinant protein which is pre-coated on a gold  label pad. The conjugates migrate upward through capillary effect and would be captured by mouse-anti human IgG antibody  immobilized in G test area subsequently and this produces a  purple-red band appears in the G test area. If it is a negative  sample, there is not a purple-red band appeared in the M and G test area. Regardless of the presence or absence of the  SARS-CoV-2 antibody in the sample, a purple-red band will appear in the quality control area (C). The purple-red band in the  quality control area (C) is a criterion for judging whether there is enough sample and whether the chromatography process is  normal. It also serves as the internal control standard for reagents.

The Explanation of the Testing Results

Positive (+): There appear purple stripes in both  quality control area and either area M or G.

Negative (-): There is only one purple stripe in the quality control area (C), and without purple stripe in  either test area M and test area G. 

Invalid: There is no purple stripe in the quality control  area (C), indicating incorrect operating procedures or  the testing strip has already deteriorated. Under this  conditions, it must read the instruction for use again  carefully, and then use the new test strips to test again.  If the problem still exists, stop using this lot number  immediately and contact the local suppliers.

image

Meanwhile, on 26th April 2020, Lepu Medical SARS-CoV-2 Antibody Test Kit went white listed officially by Chinese Commerce Ministry, please refer to the link, http://www.cccmhpie.org.cn/Pub/6325/176181.shtml , section "Coronavirus Reagent Test kits" Number 9.

Welcome to consult for more information!


Famous Hu<Marketing Director>
Beijing Sincoheren Science and Technology Development Co.ltd
Address:A-4 ,Xizhimen north str.43, Beijing, China
Whatsapp:+8614748204868


Hot Tags: covid-19 rapid testing kit with 97%+ accuracy, China, manufacturers, factory, buy,

Inquiry

You Might Also Like